Pellethane 2363-80A
Grade: 2363-80A
Overview
Polyether-based thermoplastic polyurethane with excellent flex fatigue and hydrolytic stability. A long-standing choice for catheter shafts and tubing that must stay kink-resistant in the body.
- Flexible
- Kink resistant
- Blood compatible
Technical datasheet
3% verified(3/94)At a glance
- Polyether-based TPU with excellent flex fatigue life for dynamic catheter applications.
- Hydrolytically stable, unlike polyester-based polyurethanes, which matters for prolonged body contact.
- Kink-resistant at 80A durometer, holding lumen open through tortuous vasculature.
- Carries USP Class VI, ISO 10993-4 haemocompatibility and an FDA Drug Master File.
- A long-standing, widely referenced choice for catheter shafts and medical tubing.
Identification
- Producer part number
- 2363-80A
- Nexeo material code
- Awaiting datasheet
- Resin family
- Thermoplastic polyurethane (polyether)
- Abbreviation
- TPU
- Color
- Natural / translucent
- Grade status
- Active
- Processing
- Extrusion, Injection molding
- Regional availability
- North America
Features & benefits
- Polyether soft segmentResists hydrolysis in blood and saline over prolonged contact, where a polyester-based TPU would degrade.
- High elongation at breakTubing can be stretched and flexed through tortuous anatomy without tearing or forming permanent kinks.
- Low flexural modulus relative to rigid thermoplasticsDelivers the softness a catheter shaft needs while retaining enough hoop strength to keep the lumen open.
- Excellent flex fatigue lifeSurvives the repeated bending a chronic indwelling or dynamic device sees over its service life.
- Documented haemocompatibilityISO 10993-4 blood-interaction data already exists, which is the critical package for blood-contacting devices.
Applications
Fluid path
Drug delivery
Surgical
Technical properties
| Property | Value | Unit | Test method | Conditions |
|---|---|---|---|---|
| Density | Awaiting datasheet | g/cm³ | ISO 1183 | 23 °C |
| Specific Gravity | Awaiting datasheet | g/cm³ | ASTM D792 | 23 °C |
| Melt Flow Rate | Awaiting datasheet | g/10 min | ISO 1133 | — |
| Melt Volume Rate | Awaiting datasheet | cm³/10 min | ISO 1133 | — |
| Water Absorption (24 h) | Awaiting datasheet | % | ISO 62 | 23 °C, immersion |
| Water Absorption (equilibrium) | Awaiting datasheet | % | ISO 62 | 23 °C, saturation |
| Moisture Content at Molding | Awaiting datasheet | % | ISO 15512 | max before processing |
| Mold Shrinkage (flow) | Awaiting datasheet | % | ISO 294-4 | 60 × 60 × 2 mm plaque |
| Mold Shrinkage (cross-flow) | Awaiting datasheet | % | ISO 294-4 | 60 × 60 × 2 mm plaque |
| Bulk Density | Awaiting datasheet | kg/m³ | ISO 60 | as-supplied pellet |
0 of 10 physical properties verified against a producer datasheet.
Source: pending verification — awaiting Lubrizol technical data sheet.
3% verified · 3 of 94 properties confirmed against a producer datasheet.
Typical values for reference only — not a specification. Confirm against the current producer datasheet before designing to these numbers.
Chemical resistance
| Reagent | Concentration | Rating | Exposure threshold |
|---|---|---|---|
| Isopropyl alcohol | 70% wipe | Compatible | Confirm with producer |
| Hydrogen peroxide | 3% | Compatible | Confirm with producer |
| Intralipid / lipids | 20% emulsion | Limited | Confirm with producer |
| Blood and saline | 0.9% NaCl | Compatible | Confirm with producer |
| CaviCide | as supplied | Limited | Confirm with producer |
| Sani-Cloth bleach | as supplied | Limited | Confirm with producer |
| Sodium hypochlorite | 0.5% | Not recommended | Confirm with producer |
| Acetone | 100% | Not recommended | Confirm with producer |
| DMSO | 100% | Not recommended | Confirm with producer |
Ratings describe the resin's general behaviour, not your part. Moulded-in stress, wall section, temperature and applied load all change the outcome — qualify the finished device with your own cleaning and exposure protocol.
Sterilization compatibility
| Method | Compatible | Max dose / cycles | Property retention | Discoloration |
|---|---|---|---|---|
| Gamma irradiation | Compatible | Confirm with producer | Generally well tolerated at single-dose device levels. Some cross-linking occurs, which can slightly stiffen the material. | Mild yellowing of the natural translucent colour is common and dose-dependent. |
| E-beam | Compatible | Confirm with producer | Comparable to gamma, with similar mild cross-linking. | Generally less than gamma at equivalent dose. |
| X-ray | Conditional | Confirm with producer | Expected to track gamma behaviour. | Expected to track gamma behaviour. |
| Ethylene oxide | Compatible | Confirm with producer | The preferred route for TPU. Low process temperature leaves properties unaffected. | None expected. |
| Steam autoclave | Not recommended | Not applicable | A soft thermoplastic elastomer will distort at autoclave temperature, and saturated steam drives hydrolysis of the urethane linkage. Tubing may soften, deform or lose dimensional stability. | Surface tackiness and clouding may develop. |
| Vaporized hydrogen peroxide | Conditional | Confirm with producer | Low-temperature process; bulk properties likely unaffected, though repeated oxidative exposure may affect the surface. | Minor surface effects possible over many cycles. |
| Dry heat | Not recommended | Not applicable | Dry-heat cycles run far above the service temperature of an 80A TPU; parts will soften and distort before sterility is achieved. | Thermal yellowing expected. |
Maximum dose and cycle counts require producer validation data, so we show "Confirm with producer" rather than a figure. Retention and discoloration notes are qualitative. Sterilization must always be validated on the finished device.
Regulatory & compliance
- USP Class VIYes
- ISO 10993-1 (biological evaluation)Yes
- ISO 10993-4 (blood interaction)Yes
- ISO 10993-5 (cytotoxicity)Yes
- ISO 10993-6 (implantation)Yes
- ISO 10993-10 (irritation / sensitization)Yes
- ISO 10993-11 (systemic toxicity)Yes
- FDA Drug Master FileYes
- EU MDR statusAwaiting confirmation
- Food contact statusAwaiting confirmation
- REACH SVHCAwaiting confirmation
- RoHSAwaiting confirmation
- Animal-derived-free / TSE-BSEYes
- DEHP-freeYes
- Phthalate-freeYes
- BPA-freeYes
- Latex-freeYes
- California Prop 65Awaiting confirmation
Compliance status reflects producer statements and grade records on file. Always confirm the current position with a signed regulatory statement letter for your specific device and market before submission.
Documents
- Technical Data SheetPDFRequest
- Safety Data SheetPDFRequest
- Certificate of Analysis (sample lot)PDFSign in to download
- FDA DMF reference letterPDFSign in to download
- Biocompatibility summaryPDFRequest
- Regulatory statement letterPDFRequest
- Change-notification policyPDFRequest
Documents marked “Request” are supplied on account. We link a download only when a real, current file is on file — never a placeholder that would 404.
Supply & logistics
Stocking, lead time and packaging for this grade are confirmed per order. Request a quote and the team responds with live availability rather than a figure that may be stale.
Cross-references & alternates
Alternates in our catalog
- Pellethane 2363-90ALubrizolHarder at 90A durometer · Higher flexural modulus · Less flexibleStep up in durometer when the shaft needs more pushability and burst strength, at the cost of some flexibility and kink resistance.
- Medical PVC Compound 70 Shore AContains phthalate plasticiser · Substantially lower cost · Lower flex fatigue lifeOnly where cost dominates and a plasticised material is acceptable. Note that DEHP content is increasingly restricted for paediatric and neonatal devices.
- Medical TPE CompoundLower cost · Easier overmoulding onto rigid substrates · Lower tensile strength and fatigue lifeChoose a styrenic TPE for soft-touch grips and static seals where the dynamic fatigue life of a TPU is not required.
Cross-references indicate a similar material family, not a guaranteed drop-in. Qualify any substitution against your own part and process.
Data reconciliation
A researched value disagreed with the figure already in our catalog. We keep serving the catalog value and surface the disagreement here rather than silently overwriting it — a mismatch between two published sources is itself information you may want to chase.
| Property | Served (catalog) | Researched | Source |
|---|---|---|---|
| Tensile strength at break | 34 MPa | 35.8 MPa (ASTM D412) | Published Pellethane 2363-80A literature (ASTM D412) |
| Hardness | 80 Shore A | 81 Shore A (ASTM D2240) | Published Pellethane 2363-80A literature (ASTM D2240) |
Pellethane 2363-80A — engineering FAQs
- Can Pellethane 2363-80A be autoclaved?
- No. An 80A thermoplastic polyurethane has no meaningful load-bearing stiffness at 121–134 °C, so parts soften and distort, and saturated steam also hydrolyses the urethane linkage. Ethylene oxide is the conventional route for this material, and gamma and e-beam are both listed as compatible.
- Why choose a polyether TPU over a polyester TPU for catheters?
- Hydrolytic stability. The polyether soft segment resists hydrolysis in blood and saline, whereas a polyester-based TPU degrades over prolonged wet contact. For an indwelling device that stays in the body for days or weeks, that difference decides whether the shaft retains its strength.
- Is Pellethane 2363-80A DEHP-free and phthalate-free?
- Yes. Thermoplastic polyurethane gets its softness from its own soft-segment chemistry rather than an added plasticiser, so there is no DEHP or other phthalate to leach out. This is the main reason TPU is specified in place of plasticised PVC for paediatric and neonatal fluid paths, where phthalate restrictions are tightening.
- What body contact duration is Pellethane 2363-80A qualified for?
- The grade record classifies it for prolonged contact, meaning 24 hours to 30 days under ISO 10993-1, and it carries USP Class VI along with ISO 10993 parts 4, 5 and 11. Part 4 haemocompatibility is the critical package for blood-contacting devices. For permanent implant contact beyond 30 days you would need an implant-grade material such as Zeniva ZA-500 PEEK.
- How does Pellethane 2363-80A behave after gamma sterilization?
- It is listed as gamma compatible and is generally well tolerated at single-dose device levels. Expect some cross-linking, which can slightly stiffen the material, and mild dose-dependent yellowing of the natural translucent colour. We do not publish a maximum dose here — confirm the qualified range with Lubrizol, particularly if the part is dimensionally or optically critical.
- Will lipids or lipid-based infusions affect Pellethane tubing?
- Over prolonged contact, yes. Lipids can be absorbed into the soft segment, causing swelling and some softening. It is worth qualifying specifically if the line will carry lipid emulsions such as parenteral nutrition. For short-duration contact the effect is minor.
Property comparison vs Makrolon Rx1805
Pellethane 2363-80A and Makrolon Rx1805 were tested to different standards on several properties. We only place two numbers side by side when the methods actually support it — and we say so, with the standard's own words, when they don't.
Pellethane 2363-80A
85°C
ASTM D1525
Makrolon Rx1805
144°C
ISO 306
These readings use different standards (ASTM D1525 vs ISO 306) with no documented, bounded relationship for this property.
Request both grades on a matched standard before comparing.
Pellethane 2363-80A
20-40°C
standard not stated
Makrolon Rx1805
80–120°C
standard not stated
Same property, no differing standard indicated.
Comparability is decided by test standard and condition, not by the raw number. A value under ASTM D256 (J/m) and one under ISO 180 (kJ/m²) measure different physical quantities and are never converted here.
Processing & design notes
Primary process
Injection or extrusion
Supplied in grades suited to both molding and profile or tube extrusion — confirm the specific grade with the datasheet.
Structural role
Flexible elastomer — sealing, soft-touch, and tubing functions.
Typically paired with
- A rigid PC or PP substrate for overmolding
- A compatible tubing connector resin
Engineering watch-outs
- Confirm adhesion to your chosen rigid substrate with a bond trial before committing to tooling.
- Always qualify the specific lot and grade against your own device master record and validation plan.
Qualitative guidance only. We don't publish processing windows — confirm melt and mold temperatures, drying, and shrinkage against the producer technical data sheet and your own part qualification.
- Supplier
- Lubrizol
- Certifications
- USP Class VI, FDA DMF, ISO 10993
Test Pellethane 2363-80A in your next build
Order this grade directly, or request a qualification sample first. Our team confirms availability, documentation, and shipping on every order.
Quote on request
Specialty grade — pricing varies by volume and lead time
All orders are reviewed by our sourcing team. Final pricing, lead time, and documentation (CoA, SDS) are confirmed before fulfillment.